in-famous-raccoon 9b3725464b updated README.md
2022-04-03 15:35:24 +02:00
2020-06-19 21:09:44 +02:00
2022-04-03 15:35:24 +02:00
2020-06-19 21:12:59 +02:00
2020-06-19 21:13:42 +02:00
2022-04-03 15:35:24 +02:00

Configuration on Proxmox

Install snmpd

apt install snmpd

Configure snmpd

Paste content from snmpd.conf to /etc/snmp/snmpd.conf

nano /etc/snmp/snmpd.conf

Paste content from sh file to /opt folder and make executable

nano /opt/snmp-cpu-temp.sh
chmod +x /opt/snmp-cpu-temp.sh

Run snmpd as root, because debian added the user "Debian-snmp" to the snmp.service but for SMART/LVM Status we need to be root.

edit snmpd.service and replace "Debian-snmp" with "root"

nano /lib/systemd/system/snmpd.service

From
...
ExecStart=/usr/sbin/snmpd -Lsd -Lf /dev/null -u Debian-snmp -g Debian-snmp -I -smux,mteTrigger,mteTriggerConf -f -p /run/snmpd.pid
...
To
...
ExecStart=/usr/sbin/snmpd -Lsd -Lf /dev/null -u root -g Debian-snmp -I -smux,mteTrigger,mteTriggerConf -f -p /run/snmpd.pid
...

Restart SNMPD

systemctl restart snmpd.service

Configuration on PRTG WebUI

CPU temperature

  • Add sensor
  • SNMP Custom
  • Name = CPU Temp
  • OID = .1.3.6.1.2.1.25.1.8
  • Channel Name = Temperature
  • Unit String = °C

LVM used

  • Add sensor
  • SNMP Custom
  • Name = LVM allocated pool data
  • OID = .1.3.6.1.2.1.25.1.9
  • Channel Name = LVM used
  • Unit String = %

SMART status

  • Add sensor
  • SNMP Custom String
  • Name = SMART status
  • OID = .1.3.6.1.2.1.25.1.10
  • Response Must Include (Down Status) = PASSED
  • Response Must Include (Warning Status) = PASSED

PRTG

Description
SNMP Scripts to monitor Proxmox with PRTG
Readme GPL-3.0 74 KiB
Languages
Shell 100%